Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.405
Filtrar
1.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600456

RESUMO

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Miopia , Humanos , Refração Ocular , Coma , Topografia da Córnea , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Astigmatismo/cirurgia , Substância Própria/cirurgia
2.
Sci Rep ; 14(1): 8732, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627567

RESUMO

We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Ferida Cirúrgica , Humanos , Córnea/cirurgia , Substância Própria/cirurgia , Acuidade Visual , Estudos Retrospectivos , Estudos de Casos e Controles , Cirurgia da Córnea a Laser/efeitos adversos , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Ferida Cirúrgica/cirurgia
3.
BMC Ophthalmol ; 24(1): 117, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481187

RESUMO

BACKGROUND: To report a case of interface fluid syndrome (IFS) following traumatic corneal perforation repair after small incision lenticule extraction (SMILE). CASE PRESENTATION: A 23-year-old woman, with a past history of SMILE, was struck in the left eye with a barbecue prod and subsequently underwent corneal perforation repair at local hospital. Primary wound repaired with a single 10 - 0 nylon suture at the area of leakage. After the surgery, her best corrected visual acuity (BCVA) was 20/30. Four days later, she presented at our hospital with blurred vision, and interface fluid syndrome (IFS) was diagnosed. Intraoperative optical coherence tomography (iOCT) was used to guide the resuturing of the corneal perforation in the left eye, followed by anterior chamber gas injection. At the first postoperative month, the BCVA was 20/25. The corneal cap adhered closely to the stroma, the surface became smooth. CONCLUSIONS: This case illustrates that any corneal perforation following lamellar surgery, including SMILE, may lead to IFS. It is crucial to consider the depth of corneal perforation, and intraoperative optical coherence tomography (iOCT) plays a unique role in the repair procedure.


Assuntos
Perfuração da Córnea , Cirurgia da Córnea a Laser , Miopia , Humanos , Feminino , Adulto Jovem , Adulto , Perfuração da Córnea/diagnóstico , Perfuração da Córnea/etiologia , Perfuração da Córnea/cirurgia , Miopia/cirurgia , Miopia/diagnóstico , Substância Própria/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Córnea , Tomografia de Coerência Óptica/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea , Lasers de Excimer
4.
Int Ophthalmol ; 44(1): 153, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509410

RESUMO

PURPOSE: This study aimed to measure the Raman spectrum of the human corneal stroma lens obtained from small incision lenticule extraction surgery (SMILE) in Asian myopic eyes using a confocal Raman micro-spectrometer built in the laboratory. METHODS: Forty-three myopic patients who underwent SMILE with equivalent diopters between - 4.00 and - 6.00 D were selected, and the right eye data were collected. Corneal stroma lenses were obtained during surgery, and the Raman spectra were measured after air drying. The complete Raman spectrum of human myopic corneal stroma lens tissue was obtained within the range of 700-4000 cm-1. RESULTS: Thirteen characteristic peaks were found, with the stronger peaks appearing at 937 cm-1, corresponding to proline, valine, and the protein skeleton of the human myopic corneal stroma lens; 1243 cm-1, corresponding to collagen protein; 1448 cm-1, corresponding to the collagen protein and phospholipids; and 2940 cm-1, corresponding to the amino acid and lipids, which was the strongest Raman peak. CONCLUSION: These results demonstrated that Raman spectroscopy has much potential as a fast, cost-effective, and reliable diagnostic tool in the diagnosis and treatment of eye diseases, including myopia, keratoconus, and corneal infection.


Assuntos
Cirurgia da Córnea a Laser , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Substância Própria/cirurgia , Acuidade Visual , Miopia/diagnóstico , Miopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Colágeno , Lasers de Excimer , Refração Ocular
5.
J Refract Surg ; 40(3): e133-e141, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466766

RESUMO

PURPOSE: To evaluate changes in posterior corneal asphericity (ΔQ) using the tangential radius of curvature after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) procedures. METHODS: One hundred twenty right eyes of myopic patients who underwent either FS-LASIK or SMILE procedures were analyzed using Sirius 3D corneal topography for assessment. The tangential radius was employed to calculate both preoperative and postoperative posterior corneal Q-values across each semimeridian. After both surgical interventions, the ΔQ value variations across the 360° semimeridional regions of the posterior corneal surface were compared. RESULTS: A marked postoperative increase in the posterior corneal Q-value was documented. No significant differences were noted between the postoperative Q-values or ΔQ-values of the two surgical approaches. Among patients with moderate myopia, postoperative Q-value exhibited considerably lower increases and ΔQ-value significantly smaller than their counterparts with high myopia. Moreover, the fluctuation in ΔQ across semimeridional regions was less evident in patients with moderate myopia than in those with high myopia. Notably, the degree of ΔQ fluctuation across semimeridional regions was similar between both surgical categories. These data offer insights into variations in the posterior corneal surface after refractive surgeries depending on the degree of myopia, illuminating their clinical relevance. CONCLUSIONS: Both FS-LASIK and SMILE introduce notable changes to posterior corneal asphericity among patients with different myopia intensities. Furthermore, the influence on the asphericity across the entire posterior surface is similarly distributed between FS-LASIK and SMILE techniques. [J Refract Surg. 2024;40(3):e133-e141.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ferida Cirúrgica , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Substância Própria/cirurgia , Rádio (Anatomia) , Acuidade Visual , Lasers de Excimer/uso terapêutico , Miopia/cirurgia
6.
Zhonghua Yan Ke Za Zhi ; 60(3): 275-277, 2024 Mar 11.
Artigo em Chinês | MEDLINE | ID: mdl-38462377

RESUMO

A 31-year-old female patient with refractive error in both eyes underwent small incision lenticule extraction. On the 4th day after surgery, arc-shaped peripheral corneal infiltrates appeared in the right eye. Tobramycin and dexamethasone eye drops, 0.3% gatifloxacin eye drops, and a corneal bandage lens were applied to the eye. After bacterial infection was ruled out, dexamethasone sodium phosphate was injected subconjunctivally near the corneal lesion. The symptoms improved and the corneal lesion subsided afterwards.


Assuntos
Doenças da Córnea , Cirurgia da Córnea a Laser , Miopia , Feminino , Humanos , Adulto , Substância Própria/cirurgia , Acuidade Visual , Miopia/cirurgia , Córnea/cirurgia , Cirurgia da Córnea a Laser/efeitos adversos , Doenças da Córnea/cirurgia , Soluções Oftálmicas , Topografia da Córnea , Refração Ocular , Lasers de Excimer
7.
J Fr Ophtalmol ; 47(4): 104085, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38377878

RESUMO

PURPOSE: To evaluate the safety, efficacy and postoperative visual quality of small incision lenticule extraction (SMILE) and Wavefront-Guided Laser in situ keratomileusis (WFG-LASIK) and to analyze their efficacy in correcting astigmatism. METHODS: A systematic literature search was performed using Cochrane Collaboration methodology. Databases searched included PubMed, Embase, the Cochrane Library and Web of Science. RevMan software version 5.3.0 was used for meta-analysis. RESULTS: A total of 976 eyes were included in 8 studies, of which 539 eyes underwent SMILE and 437 eyes underwent WFG-LASIK. There were no statistically significant differences in the proportion of eyes achieving uncorrected distance visual acuity of 20/20 or better (P=0.18), the proportion of eyes within±0.50 diopter of target refraction postoperatively (P=0.10), or the postoperative magnitude of cylinder (P=0.10). Regarding the Alpins vector analysis of astigmatism, there was no statistically significant difference in the surgical magnitude of error (P=0.09) between the two groups. WFG-LASIK has a lower surgical angle of error (P= 0.002) and higher surgical correction index of cylinder (P=0.03) than SMILE. In terms of aberrations, higher order aberrations (P=0.46), spherical aberrations (P=0.22) and trefoil (P=0.56) were not statistically different, while WFG-LASIK induced less coma than SMILE surgery (P=0.02). CONCLUSION: Both SMILE and WFG-LASIK are safe and effective ways to correct myopia and astigmatism. Compared with SMILE, WFG-LASIK has a lower surgical angle of error, higher surgical correction index of cylinder and induces less coma.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ferida Cirúrgica , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Astigmatismo/cirurgia , Coma/cirurgia , Lasers de Excimer/uso terapêutico , Estudos Prospectivos , Refração Ocular , Córnea , Substância Própria/cirurgia , Miopia/cirurgia , Resultado do Tratamento
8.
Int Ophthalmol ; 44(1): 52, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38340212

RESUMO

PURPOSE: To evaluate the initial visual outcomes of Small Incision Lenticule Extraction (SMILE) Pro® using a 2 MHz femtosecond laser (VisuMax 800, Carl Zeiss Meditec) and to assess the efficacy, safety, predictability, accuracy, and complication rate. METHODS: This retrospective analysis included eyes which underwent the SMILE Pro® procedure using VisuMax 800 femtosecond laser to correct myopia. All surgeries were performed by one surgeon (DB). Follow-up was conducted 3 months postoperatively to evaluate visual outcomes after neuroadaptation, corrected visual acuity (CDVA) and intra- and postoperative complications. RESULTS: One hundred and fifty-two eyes of 82 patients (mean age 31 ± 6 years) results at 3 months are presented. The mean spherical equivalent (SE) was - 4.44 ± 1.86 D preoperatively while -0.24 ± 0.32 D postoperatively. 99% of eyes achieved SE within ± 1.0 D of attempted correction and 91% were within ± 0.5 D. Efficacy index was 0.93 while the safety index was 1. No complications occurred intra- or postoperatively. No eyes lost more than 1 line of their preoperative CDVA. All highly myopic eyes (- 6.25 to - 10.00 D; n = 18) achieved 20/20 at 3 months postoperatively and were within 0.5 D from the attempted SE and no eyes lost more than 1 line of CDVA. CONCLUSION: The SMILE Pro® is a safe, efficient, and predictable procedure for the treatment of myopia and myopic astigmatism, with comparable results of conventional SMILE surgery. High myopic eyes achieve better results than low and moderate myopia. No complications were recorded in our patients.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Adulto , Acuidade Visual , Estudos Retrospectivos , Refração Ocular , Córnea/cirurgia , Substância Própria/cirurgia , Miopia/cirurgia , Astigmatismo/cirurgia , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
9.
Int Ophthalmol ; 44(1): 50, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336951

RESUMO

PURPOSE: Intrastromal corneal ring segment (ICRS) implantation is a surgical technique developed with the purpose of avoiding the progression of corneal protrusion and is considered a viable option for managing patients with keratoconus as it stabilizes or improves vision thus delaying or excluding the need of more advanced surgical intervention such as penetrating keratoplasty. However, long term follow up is still limited to determine its actual success in achieving this goal. The current project aims to provide an extended follow up reporting a mean followup of around 5 years, extending up to 12.5 years. METHODS: We recruited patients who performed their ICRS between 2008 and 2013. We contacted patients for a follow up exam with a possible corneal tomography. For each patient, we obtained baseline pre operative data and latest follow up data which included visual acuity, subjective refraction, clinical slit-lamp exam, and corneal tomography. We compared the change in best corrected visual acuity and maximum keratometry readings from clinical visits before ring implantation to the latest follow up. RESULTS: A total of 68 eyes for 53 patients were included. The mean duration of follow up was 53.87 (± 38.8) months, with a maximum duration of 153 months. We found a significant improvement in corrected and uncorrected visual acuity, keratometries and refraction during the follow up period. On correlation analysis, strong negative significant correlation was found between duration since surgery and change in uncorrected visual acuity (p = 0.03, ρ = 0.338) and mean keratometry values (p = 0.033, ρ = 0.296). At the latest follow up for majority of patients with more than 100 weeks of follow up (12 eyes), uncorrected visual acuity were equal to or worse than baseline. CONCLUSION: This study represents the largest follow up for ICRS implanted in keratoconus patients. Improvement of visual acuity following ICRS implantation can be expected in the first few years, after which, a decline occurring thereafter.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Ceratocone/cirurgia , Seguimentos , Substância Própria/cirurgia , Topografia da Córnea , Implantação de Prótese , Refração Ocular , Próteses e Implantes , Estudos Retrospectivos
10.
Indian J Ophthalmol ; 72(5): 745-747, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38389247

RESUMO

Lamellar surgeries have revolutionized our understanding and practice of keratoplasties. However, the learning curve in deep anterior lamellar keratoplasty (DALK) makes it daunting for novice surgeons. This paper describes a unique intraoperative sign - the radial "spike sign," which heralds the commencement of a big bubble in some cases of advanced keratoconus in eyes that have not undergone any previous surgery. The spike sign was noted during big bubble DALK surgery and was then retrospectively looked for in recorded DALK surgical videos and correlated with the formation of a big bubble. The movement of air after injection was classified into the direct formation of a big bubble, stromal emphysema with no big bubble, and emphysema with the spike sign followed by a big bubble. In total, 104 surgical videos of big bubble attempts were evaluated and classified as such. The spike sign helps reduce the number of unnecessary attempts at big bubble formation during DALK, thus improving surgical outcomes.


Assuntos
Transplante de Córnea , Ceratocone , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Transplante de Córnea/métodos , Estudos Retrospectivos , Masculino , Complicações Intraoperatórias , Acuidade Visual , Adulto , Feminino , Substância Própria/cirurgia , Substância Própria/patologia
11.
PLoS One ; 19(2): e0288181, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38319899

RESUMO

OBJECTIVES: To identify predictive factors and to construct predictive models using epidemiological and clinical preoperative factors for the visual acuity change after intracorneal ring segment (ICRS) implantation in patients with keratoconus. METHODS: The medical records of 287 keratoconic eyes of 230 patients implanted with ICRS at Chula Refractive Surgery Center of a tertiary university hospital (Bangkok, Thailand) between January 2012 and March 2022 were retrospectively reviewed for epidemiological and clinical preoperative variables, including those derived from Scheimpflug tomography. After randomly excluding one eye for each bilateral case, the remaining 230 eyes were randomized into two groups: a training group (184 eyes) and a validation group (46 eyes). In the training group, the correlation between the interesting variables and postoperative uncorrected and corrected distance visual acuity change (ΔUDVA and ΔCDVA; logMAR scale) at 6 months was explored, and then the multiple linear regression analysis was used to develop the predictive models. The obtained models were tested using the validation group. RESULTS: There were 5 and 14 preoperative variables that statistically correlated with ΔUDVA and ΔCDVA respectively. Only the preoperative corrected distance visual acuity (CDVAp) strongly correlated with ΔCDVA (Beta = -0.746). Using multiple regression, the preoperative uncorrected distance visual acuity (UDVAp) and front mean keratometry were selected in the proposed model for ΔUDVA (adjusted R2 = 38.8%), while the CDVAp and index of surface variance (ISV) were selected in the model [Formula: see text] (adjusted R2 = 48.9%). The ΔUDVA and ΔCDVA models were correct in 47.83% and 63.4% of the validation group within 0.20 logMAR, respectively. CONCLUSIONS: Potential predictive factors and models for ICRS-induced changes in visual acuity are proposed as adjunctive tools for clinicians. Such tools could be used for case selection and during counselling before ICRS implantation to maximize surgical outcomes.


Assuntos
Ceratocone , Humanos , Substância Própria/cirurgia , Topografia da Córnea , Olho Artificial , Ceratocone/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Refração Ocular , Estudos Retrospectivos , Tailândia
12.
Cornea ; 43(3): 398-401, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38315501

RESUMO

ABSTRACT: Corneal allogeneic intrastromal ring segments (CAIRS) refer to the placement of allogeneic rings and segments in intrastromal channels within the cornea. Currently, a deepithelialized donor cornea is used as the allogeneic source for CAIRS and the cut ring is turned sideways and implanted so that the thickness can be varied by varying the distance between the concentric trephine blades. In addition, to obtain a greater effect, CAIRSs are preferred to be implanted with the Bowman layer (BL) facing the corneal apex and posterior stroma facing limbally. Being flexible tissue, it is, however, important to prevent twisting and to maintain correct orientation. We describe a simple technique of marking the BL with a gentian violet surgical marker to simplify CAIRS insertion. BL marking allows easy visibility of twists and helps identify improper orientation, thus allowing correct insertion of CAIRS.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Ceratocone , Humanos , Substância Própria/cirurgia , Córnea/cirurgia , Próteses e Implantes , Implantação de Prótese , Topografia da Córnea , Ceratocone/cirurgia
14.
J Cataract Refract Surg ; 50(5): 518-522, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38251934

RESUMO

PURPOSE: To describe a new technique for preparing corneal allogenic ring segments (CAIRSs) using femtosecond laser technology. SETTING: Hospital Foundation Adolphe de Rothschild-Noémie de Rothschild institute, Paris, France. DESIGN: Preclinical study conducted on human corneal grafts. METHODS: The corneal grafts were mounted on an artificial chamber pressurizer (ACP) with preset constant pressure, and the FSL was used to create a circular annulus with specific dimensions. The resulting CAIRSs were analyzed for their thickness and width after air drying. RESULTS: A total of 25 CAIRSs were prepared using the FSL. The mean width and thickness of the CAIRSs were 803 ± 77 µm and 83 ± 16 µm, respectively. Statistical analysis revealed no significant differences in width among the various quadrants of each CAIRS or between different CAIRSs. Significantly thicker CAIRSs were obtained with a higher ACP pressure. CONCLUSIONS: The technique of CAIRS preparation using FSL technology and controlled artificial anterior chamber pressure demonstrated reproducibility and precision. This approach holds the potential for customizing and personalizing CAIRSs based on individual corneal characteristics.


Assuntos
Transplante de Córnea , Humanos , Transplante de Córnea/métodos , Implantação de Prótese/métodos , Doadores de Tecidos , Substância Própria/cirurgia , Próteses e Implantes , Córnea/cirurgia , Transplante Homólogo , Reprodutibilidade dos Testes
15.
J Cataract Refract Surg ; 50(5): 523-533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288954

RESUMO

Corneal crosslinking (CXL) is used for treating keratoconus and post-laser in situ keratomileusis ectasia. However, refractive surgery is not usually performed with prophylactic CXL. Therefore, we performed a meta-analysis comparing outcomes of refractive surgeries with vs without prophylactic CXL. We systematically searched databases for studies comparing refractive surgeries for myopic correction with vs without prophylactic corneal crosslinking. Review Manager 5.4.1 was used to perform statistical analysis. We included 2820 eyes from 28 studies. Compared with refractive surgery alone, surgery with prophylactic CXL resulted in decreased central corneal thickness, corrected distance visual acuity logMAR, and safety and efficacy indices. There were no significant differences in postoperative uncorrected distance visual acuity of 20/20 or better at ≥12 months and other visual outcomes among both groups. More randomized controlled trials with standard crosslinking protocols are needed to analyze the prophylactic use of crosslinking with refractive surgeries.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Fármacos Fotossensibilizantes , Riboflavina , Acuidade Visual , Humanos , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Riboflavina/uso terapêutico , Colágeno/metabolismo , Acuidade Visual/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Fotoquimioterapia/métodos , Lasers de Excimer/uso terapêutico , Substância Própria/metabolismo , Substância Própria/cirurgia , Raios Ultravioleta , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia
16.
BMC Ophthalmol ; 24(1): 13, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191381

RESUMO

PURPOSE: To characterize the in vivo corneal epithelial thickness (CET) remodeling profile in a population of eyes after small incision lenticule intrastromal keratoplasty (SMI-LIKE) for hyperopia. METHODS: The CET profile was measured by RTVue-100 Fourier-domain OCT system across the central 6-mm diameter of the cornea of 17 eyes from 12 subjects (five males and seven females) who accepted corneal stromal lens implantation surgery for correcting hyperopia. The CET were measured at positions with a radius of 0-1.0 mm, 1.0-2.5 mm (divided into eight quadrants) and 2.5-3.0 mm (divided into eight quadrants) from the corneal center. Corneal maximum simulated keratometry (Km) was measured by Pentacam HR anterior segment analyzer to analyze CET changes. The examination data of subjects were collected in four time periods, which were preoperative, short-term postoperative (one week after surgery), mid-term postoperative (the last review within 3-6 months after surgery), and long-term postoperative (the last review over 1-2.5 years after surgery). The changes of CET were compared and analyzed in the four time periods. RESULTS: Mean CET in 0-1.0 mm, 1.0-2.5 mm and 2.5-3.0 mm of the cornea decreased in one week after surgery, respectively, as compared to CET in the preoperative period, which turned from 55.06 ± 0.82 µm、54.42 ± 0.75 µm、53.46 ± 0.60 µm to 51.18 ± 1.05 µm (P = 0.005), 49.38 ± 0.70 µm (P = 0.000), 51.29 ± 0.59 µm (P = 0.025). In the mid-term postoperative period, mean CET in 0-1.0 mm and 1.0-2.5 mm areas kept thinner than mean CET in the preoperative period, CET in 0-1.0 mm is 50.59 ± 0.76 µm (P = 0.000),CET in 1.0-2.5 mm is 50.23 ± 0.57 µm (P = 0.000), while mean CET in 2.5-3.0 mm area recovered to the same thickness as the preoperative level, which is 54.36 ± 0.66 µm (P = 1.000), until the long-term period, CET stabilized in the above doughnut pattern. CONCLUSIONS: After stromal lenticule implantation for hyperopia, CET showed a remodeled form of thinning in the 0-2.5 mm area and thickening in the 2.5-3.0 mm area, and remained stable within one year after surgery.


Assuntos
Transplante de Córnea , Hiperopia , Feminino , Masculino , Humanos , Hiperopia/cirurgia , Tomografia de Coerência Óptica , Córnea , Substância Própria/cirurgia
17.
Indian J Ophthalmol ; 72(Suppl 2): S308-S311, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271428

RESUMO

The aim of this paper is to present the surgical technique of selective Bowman's layer transplantation as well as the results of the surgery in patients with trophic corneal ulcers. The methodology of the study included three eyes from three patients with neurotrophic corneal ulcers grafting with corneal Bowman's layer. Pre- and postoperative analyses of the anterior segment of the eye were based on optical coherence tomography and slit-lamp assessment. Postoperatively a gradual corneal stroma restoration and fast corneal epithelialization were noticed. Based on our observations, the stiff and firm structure of Bowman's layer is supposed to strengthen the corneal surface and maintain its shape. It acts also as an antipathogen and antitoxin corneal barrier. Application of this acellular corneal layer transplantation to cover trophic corneal ulcers is an interesting, modern and crucial method of neurotrophic keratitis treatment.


Assuntos
Distrofias Hereditárias da Córnea , Úlcera da Córnea , Humanos , Úlcera da Córnea/diagnóstico , Úlcera da Córnea/cirurgia , Úlcera , Córnea/cirurgia , Substância Própria/cirurgia
18.
Indian J Ophthalmol ; 72(Suppl 2): S167-S175, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271413

RESUMO

Keratoconus is a corneal disorder characterized by the progressive thinning and bulging of the cornea. Currently, the major goal of management is to halt its progression, restore normal corneal strength, prevent acute complications, and save vision. Penetrating keratoplasty and deep anterior lamellar keratoplasty as conventional surgical methods for advanced keratoconus are limited by relatively high rates of immune intolerance, slow post-operational recovery, high costs, and shortage of donor corneas. Recently, the development of lenticule addition keratoplasty enables the restoration of corneal thickness simply by implanting a lenticule into the stromal pocket created with the femtosecond laser, which can originate from cadaver corneas or more appealing, be extracted from patients via a small-incision lenticule extraction (SMILE) surgery. As the first systematic review in this field, we critically review publications on lenticule addition keratoplasty and provide our perspectives on its clinical application and the focus of future research.


Assuntos
Transplante de Córnea , Ceratocone , Humanos , Ceratocone/cirurgia , Transplante de Córnea/métodos , Córnea/cirurgia , Ceratoplastia Penetrante/métodos , Lasers , Substância Própria/cirurgia
19.
BMC Ophthalmol ; 24(1): 45, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287289

RESUMO

BACKGROUND: To evaluate the possible topographic and surgical risk factors for high postoperative residual astigmatism in patients who undergo small-incision lenticule extraction (SMILE) surgery and have different myopia degrees. METHODS: A retrospective cohort study was conducted, and patients who underwent SMILE surgery were enrolled. A total of 80 and 150 eyes from 40 to 75 individuals, respectively, were selected as the low myopia and high myopia groups. The demographic data, visual acuity, refraction, topographic parameters and surgical settings were recorded. Multiple linear regression with interaction tests were performed to survey the risk factors for high postoperative residual astigmatism in each group. RESULTS: Five (6.25%) and 9 (6.00%) eyes presented with high postoperative residual astigmatism in the low myopia and high myopia groups, respectively, but these differences were not significant (P = 0.569). A steep corneal curvature was correlated with a greater risk of high postoperative residual astigmatism in the low myopia group (P = 0.015), while a higher degree of cycloplegic cylinder power, steeper corneal curvature, greater topographic cylinder power, smaller optic zone and longer incision length were associated with a high rate of postoperative residual astigmatism in the high myopia group (all P < 0.05). In addition, the interaction effects of cycloplegic and topographic cylinder power and longer incision length on the incidence of high postoperative residual astigmatism development were more evident in the high myopia group than in the low myopia group (all P < 0.05). CONCLUSIONS: A steep corneal curvature correlates with a high risk of high postoperative residual astigmatism after SMILE surgery, and a higher degree of cycloplegic and topographic cylinder and longer incision are associated with high postoperative residual astigmatism in individuals with high myopia.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Midriáticos , Topografia da Córnea , Microcirurgia , Refração Ocular , Miopia/cirurgia , Córnea/cirurgia , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico
20.
Cornea ; 43(2): 190-194, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37039699

RESUMO

PURPOSE: The aim of this study was to evaluate the quality of life (QOL) after intrastromal ring implantation in patients with keratoconus. METHODS: This was a prospective, randomized, interventional study. We analyzed 60 eyes of 30 patients aged 16 to 35 years who were treated at the Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, Brazil. The Visual Function Questionnaire (VFQ-25) and Short-Form 36 Questionnaire (SF-36) were used before intracorneal ring segment (ICRS) implantation and at 3, 6, and 12 months after surgical intervention. RESULTS: The mean corrected visual acuity improved from a mean of 0.32 ± 0.2 logMAR (20/40) preoperatively to 0.14 ± 0.11 logMAR (20/25) 1 year postoperatively ( P = 0.001). The mean spherical equivalent varied from -7.24 ± 3.47 preoperatively to -4.13 ± 2.41 postoperatively ( P = 0.001). The overall composite score for the VFQ-25 improved from 55.1 preoperatively to 80.4 1 postoperatively ( P = 0.001). SF-36 showed statistically significant improvement in all scores. When analyzing the correlation between visual acuity and VFQ composite score, a significant correlation was found between both variables (Pearson correlation coefficient of -0.40, P = 0.001). CONCLUSIONS: Patients with keratoconus had increased psychological symptoms and lower QOL and improved psychosocial criteria associated with corneal remodeling and decreased visual dependence on others after surgery. Extrapolation of these data to the whole keratoconus population suggests that ICRS implantation could improve QOL in these patients.


Assuntos
Ceratocone , Humanos , Substância Própria/cirurgia , Topografia da Córnea , Estudos Prospectivos , Próteses e Implantes , Implantação de Prótese , Qualidade de Vida , Refração Ocular , Adolescente , Adulto Jovem , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...